How to Connect X1 Genki 6kW (X1 Hybrid LV) Two Inverters in Parallel?

Fronus Solar Energy

Solar adoption in Pakistan has seen a major rise due to increasing electricity costs and frequent power outages. Many households and businesses are now shifting towards larger solar systems to secure reliable and uninterrupted energy. In such cases, a single inverter often does not meet the growing energy demand, especially when appliances, air conditioners, and machinery need consistent supply. To overcome this limitation, users prefer connecting two inverters in parallel, which allows them to expand system capacity without replacing their existing setup.

The Fronus X1 Genki 6kW Hybrid LV inverter is designed to support parallel operation, making it a practical and efficient choice for anyone planning to scale their solar system. By running two inverters together, you not only double the output power but also improve system flexibility and reliability. This approach is particularly useful for medium to large households, shops, and small industries in Pakistan where electricity demand keeps increasing.

In this guide, we will explain how to connect two X1 Genki 6kW inverters in parallel and discuss the key benefits of adopting this configuration for your solar power system.

Why Parallel Connection Matters

  • Expands total output capacity. Two 6kW inverters give you up to 12kW of power.
  • Balances heavy household and commercial loads.
  • Ensures backup when one inverter is under maintenance.
  • Allows step-by-step expansion without replacing older equipment.

Key Features of Fronus X1 Genki 6kW Hybrid LV

Before learning about parallel connection, review the main features:

  • Max. PV Input Power: 12,000W
  • PV Input Voltage Range: 80–520V
  • Nominal Battery Voltage: 48V
  • Max. Charging/Discharging Current: 120A
  • Nominal Output Apparent Power: 6000VA
  • Max. Efficiency: 97.6%
  • MPPT Efficiency: >99.9%
  • Protection Rating: IP65 (dust and water-resistant)
  • Cooling: Smart cooling, transformerless design
  • Interfaces: LED, LCD, RS485, CAN, USB, NTC, WiFi+LAN
  • Warranty: 5 years

These specifications make the X1 Genki Hybrid LV reliable for both residential and small commercial setups.

Fronus Solar Energy

Step-by-Step Guide to Parallel Connection

1. Pre-Installation Checklist

  • Confirm both inverters are the same model (X1 Genki 6kW Hybrid LV).
  • Update firmware of both units to the latest version.
  • Ensure identical battery type and capacity if using storage.
  • Prepare communication cables (RS485/CAN).
  • Arrange proper circuit breakers and fuses for safety.

2. AC Wiring

  • Connect both inverters to the main distribution board.
  • Ensure output phases are matched.
  • Use recommended cable thickness to handle high current.

3. DC Wiring

  • Connect solar panels to each inverter separately according to design.
  • Each inverter should handle its own PV strings.
  • Ensure correct polarity and secure all terminals.

4. Battery Connection

  • Use identical battery banks for both inverters.
  • Connect batteries in parallel with equal cable length to prevent imbalance.
  • Install fuses between battery and inverter.

5. Communication Setup

  • Use RS485 or CAN communication ports.
  • Designate one inverter as the “Master” and the other as “Slave.”
  • Connect communication cable from Master to Slave.
  • Configure settings on the LCD screen for parallel operation.

6. Synchronization

  • After wiring, power on both inverters.
  • Access inverter settings and enable parallel function.
  • Verify synchronization by checking LCD status.
  • Test load sharing between both inverters.

Safety Precautions

  • Always disconnect AC and DC breakers before wiring.
  • Use insulated tools and safety gloves.
  • Ensure proper grounding of both inverters.
  • Install surge protection devices.
  • Do not exceed 3000 meters altitude or 45°C continuous operation.

Common Mistakes to Avoid

  • Mixing different inverter models.
  • Using batteries of different capacities.
  • Skipping firmware updates.
  • Ignoring communication wiring.
  • Installing without proper circuit protection.
Fronus Solar Energy

Why Choose Fronus X1 Genki for Parallel Connection

  • High efficiency up to 97.6%.
  • Robust IP65 protection for outdoor installation.
  • Smart cooling extends inverter life.
  • Local service and 5-year warranty.
  • Supports both lithium and lead-acid batteries.

Final Thoughts

Connecting two X1 Genki 6kW Hybrid LV inverters in parallel offers an effective way to expand your solar system. By linking the inverters, you can increase the total system capacity to 12kW, which is ideal for large homes, shops, offices, and businesses that have high energy consumption. This setup gives you greater flexibility to manage loads, run multiple appliances at the same time, and reduce dependency on the national grid.

The parallel connection does more than just increase power. It improves system reliability because even if one inverter goes offline, the other continues to supply electricity. This ensures uninterrupted power, which is important for households and businesses in Pakistan that face frequent voltage drops and load shedding. With proper installation, communication cable setup, and safety checks, the two inverters work in perfect sync, balancing the energy load efficiently.

Fronus also adds value by providing advanced features such as high MPPT efficiency, smart cooling, strong protection systems, and multiple communication interfaces. These features make monitoring and performance management simple for the user. On top of that, Fronus offers local support and warranty coverage in Pakistan, giving you peace of mind that your investment is secure.

For anyone looking to scale their solar power setup, the X1 Genki Hybrid LV inverter in parallel connection is one of the best options available. It combines higher output, advanced technology, and reliable after-sales support, making it a top choice for parallel hybrid inverter systems in Pakistan.

Click on the image to Fronus Solax Latest Products 

Fronus Solax Contact:

Or contact via WhatsApp for Inverter & Batteries: 0313-7867164



Previous Post Next Post